Tzu Chi Medical Journal
Volume 20, Issue 4 , Pages 253-269, December 2008

Clinical Applications and Usefulness of Integrated Single Photon Emission Computed Tomography/Computed Tomography Imaging

  • Pan-Fu Kao

      Affiliations

    • Department of Nuclear Medicine, Buddhist Tzu Chi General Hospital, Taipei Branch, Taipei, Taiwan
    • Department of Radiological Technology, Tzu Chi College of Technology, Hualien, Taiwan
    • Corresponding Author InformationCorresponding author. Department of Nuclear Medicine, Buddhist Tzu Chi General Hospital, Taipei Branch, 289, Jianguo Road, Xindian City, Taipei, Taiwan
  • ,
  • Yu-Hsiang Chou

      Affiliations

    • Department of Nuclear Medicine, Buddhist Tzu Chi General Hospital, Taipei Branch, Taipei, Taiwan

Received 31 March 2008; received in revised form 14 April 2008; accepted 1 May 2008.

Article Outline

Abstract 

Radiopharmaceuticals reflect physiologic and pathologic functions rather than anatomical abnormalities. In the clinical setting, it is often necessary to correlate these functional studies using anatomical imaging. The advent of single photon emission computed tomography (SPECT) and positron emission tomography (PET) provides tomographic images for direct correlation to anatomic modalities such as X-ray, computed tomography (CT) and magnetic resonance imaging. Correlation of anatomic and functional information can aid in the decision-making process by enabling better localization and definition of organs and lesions and improving the precision of surgical biopsies. The advantages of combining SPECT with CT are primarily due to the anatomical referencing and the attenuation correction capabilities of CT. Depending on the system design, there are varying technical issues surrounding the different SPECT/CT devices. The principle of the integrated SPECT/CT instrumentation and the use of attenuation correction and anatomical referencing are discussed in this review. The specific disease processes where SPECT/CT has had a positive impact on diagnostic accuracy will be illustrated in this review. Although it is starting more slowly than PET/CT, SPECT/CT has many existing and potential areas of clinical application and has significantly added to the diagnostic power of nuclear medicine. Through literature review and case presentation, the authors illustrate the applications and uses of SPECT/CT as experienced at Tzu Chi General Hospital. The most common uses of SPECT/CT were for the diagnoses of infections focused with gallium-67 citrate, 99mTc-sulfurcolloid sentinel lymph node mapping, thyroid cancer survey with 131I-sodium iodide, parathyroid scan with 99mTc-Sestamibi, abdominal diseases, and bone imaging with 99mTc-methylene diphosphonate. Through this review, the authors also highlight the current comprehensive clinical use of SPECT/CT in our hospital.

Keywords:  Bone scan , 67Ga inflammation scan , Parathyroid scan , Sentinel lymph node , Single photon emission computed tomography/computed tomography (SPECT/CT) , Thyroid cancer survey

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. von Schulthess G . Introduction . In:  von Schulthess G editors. Molecular Anatomic Imaging: PET-CT and SPECT-CT Integrated Modality Imaging . 2nd ed.. Philadelphia: Lippincott Williams & Wilkins; 2007;p. 3–9
  2. Bocher M , Balan A , Krausz Y , et al.   Gamma camera-mounted anatomical X-ray tomography: technology, system characteristics and first images . Eur J Nucl Med . 2000;27:619–627
  3. O'Connor MK , Kemp BJ . Single photon emission computed tomography/computed tomography: basic instrumentation and innovations . Semin Nucl Med . 2006;36:258–266
  4. Hasagawa BH , Stebler B , Rutt BK . A prototype high-purity germanium detector system with fast photon counting circuitry for medical imaging . Med Phys . 1991;18:900–999
  5. Lang TF , Hasagawa BH , Liew SC , et al.   Description of a prototype emission transmission computed tomography imaging system . J Nucl Med . 1992;33:1881–1887
  6. Kalki K , Blankespoor SC , Brown JK , et al.   Myocardial perfusion imaging with a combined x-ray CT and SPECT system . J Nucl Med . 1997;38:1535–1540
  7. Tang HR , Da Silva AJ , Matthay KK , et al.   Neuroblastoma imaging using a combined CT scanner–scintillation camera and 131I-MIBG . J Nucl Med . 2001;42:237–247
  8. King MA , Tsui BM , Pan TS , Glick SJ , Soares EJ . Attenuation compensation for cardiac single-photon emission computed tomographic imaging: part 2. Attenuation compensation algorithms . J Nucl Cardiol . 1996;3:55–64
  9. Hutton BF , Hudson HM , Beekman FJ . A clinical perspective of accelerated statistical reconstruction . Eur J Nucl Med . 1997;24:797–808
  10. Love C , Palestro CJ . Radionuclide imaging of infection . J Nucl Med Technol . 2004;32:47–57
  11. De Winter F , Gemmel F , Van Laere K , et al.   99mTcciprofloxacin planar and tomographic imaging for the diagnosis of infection in the postoperative spine: experience in 48 patients . Eur J Nucl Med Mol Imaging . 2004;31:233–239
  12. Yapar Z , Kibar M , Yapar AF , Togrul E , Kayaselcuk U , Sarpel Y . The efficacy of technetium-99m ciprofloxacin (infection) imaging in suspected orthopaedic infection: a comparison with sequential bone/gallium imaging . Eur J Nucl Med . 2001;28:822–830
  13. Bleeker-Rovers CP , Vos FJ , Wanten GJ , et al.   18F-FDG PET in detecting metastatic infectious disease . J Nucl Med . 2005;46:2014–2019
  14. Love C , Tomas MB , Tronco GG , Palestrol CJ . FDG PET of infection and inflammation . Radiographics . 2005;25:1357–1368
  15. Hoffer P . Gallium: mechanisms . J Nucl Med . 1980;21:282–285
  16. Newman RD , McAfee JG . Gallium-67 imaging in infection . In:  Sandler MP ,  Coleman RE ,  Patton JA editor. Diagnostic Nuclear Medicine . 4th ed.. Philadelphia: Lippincott, Williams & Wilkins; 2004;p. 1205–1217
  17. Kao PF , Tsui KH , Leu HS , Tsai MF , Tzen KY . Diagnosis and treatment of pyogenic psoas abscess in diabetic patients: usefulness of computed tomography and gallium-67 scanning . Urology . 2001;57:246–251
  18. Kao PF , Tzen KY , Tsui KH , Tsai MF , Yen TC . The specific gallium-67 scan uptake pattern in psoas abscesses . Eur J Nucl Med . 1998;25:1442–1447
  19. Kao PF , Chen KS , Tsai MF , Ng SH , Tzen KY . Repeated gallium-67 scan demonstrating an occult mycotic aneurysm of the aortic arch due to Salmonella . Scand J Infect Dis . 2003;35:199–202
  20. Tzen KY , Yen TC , Yang RS , Lee CM , Kao PF , Lin KJ . The role of 67Ga in the early detection of spinal epidural abscesses . Nucl Med Commun . 2000;21:165–170
  21. Kao PF , Tzen KY , Tsai MF , Chen FP . Pyometra as a lower abdominal doughnut sign on a Ga-67 scan . Clin Nucl Med . 2000;25:485–486
  22. Kao PF , Tzen KY , Tsai MF , Yang KJ . Gallium-67 scanning in endogenous Klebsiella endophthalmitis with unknown primary focus . Scand J Infect Dis . 2000;32:326–328
  23. Swayne LC . Computer-assisted fusion of single-photon emission tomographic and computed tomographic images. Evaluation in complicated inflammatory disease . Invest Radiol . 1992;27:78–83
  24. Bar-Shalom R , Yefremov N , Guralnik L , et al.   SPECT/CT using 67Ga and 111In-labeled leukocyte scintigraphy for diagnosis of infection . J Nucl Med . 2006;47:587–594
  25. Kao PF , Huang MJ , You DL , Tzen KY . Using 131I MIBG and 99mTC-MDP bone scan for localization of rare extra-adrenal pheochromocytomas: report of 2 cases . J Formos Med Assoc . 1992;91(Suppl 4):S283–S287
  26. Kao PF , Tzen KY , Huang MJ , You DL . Obstructive hydronephrosis with I-131 MIBG accumulation mimicking huge pheochromocytoma: a diagnosis pitfall found with Tc-99m MDP imaging . Clin Nucl Med . 1996;21:994–995
  27. Kao PF , Chang HY , Tsai MF , Lin KJ , Tzen KY , Chang CN . Breast uptake of iodine-131 mimicking lung metastases in a thyroid cancer patient with a pituitary tumour . Br J Radiol . 2001;74:378–381
  28. Leitha T , Staudenherz A . Frequency of diagnostic dilemmas in 131I whole body scanning . Nuklearmedizin . 2003;42:55–62
  29. Krausz Y , Klein M , Uziely B , et al.   Impact of SPECT/CT on assessment of I-131 avid sites in differentiated thyroid cancer . J Nucl Med . 2004;45:349
  30. Ruf J , Lehmkuhl L , Bertram H , et al.   Impact of SPECT and integrated low-dose CT after radioiodine therapy on the management of patients with thyroid carcinoma . Nucl Med Commun . 2004;25:1177–1182
  31. Tharp K , Israel O , Hausmann J , et al.   Impact of 131I-SPECT/CT images obtained with an integrated system in the followup of patients with thyroid carcinoma . Eur J Nucl Med Mol Imaging . 2004;31:1435–1442
  32. O'Doherty MJ , Kettle AG , Wells P , Collins RE , Coakley AJ . Parathyroid imaging with technetium 99m-sestamibe: preoperative localization and tissue uptake studies . J Nucl Med . 1992;33:313–318
  33. Takebayashi S , Hidai H , Chiba T , Takaga Y , Nagatani Y , Matsubara S . Hyperfunctional parathyroid glands with 99mTC-MIBI scan: semi-quantitative analysis correlated with histologic findings . J Nucl Med . 1999;40:1792–1797
  34. Ohshima A , Simizu S , Okido M , Shimada K , Kuroki S , Tanaka M . Endoscopic neck surgery: current status for thyroid and parathyroid diseases . Biomed Pharmacother . 2002;56:48s–52s
  35. Medrano C , Hazelrigg SR , Landreneau RJ , Boley TM , Shawgo T , Grasch A . Thoracoscopic resection of ectopic parathyroid glands . Ann Thorac Surg . 2000;69:221–223
  36. Denham DW , Norman J . Cost-effectiveness of preoperative sestamibi scan for primary hyperparathyroidism is dependent solely upon the surgeon's choice of operative procedure . J Am Coll Surg . 1998;186:293–305
  37. Gotthardt M , Lohmann B , Behr TM , et al.   Clinical value of parathyroid scintigraphy with technetium-99m methoxyisobutylisonitrile: discrepancies in clinical data and a systematic meta-analysis of the literature . World J Surg . 2004;28:100–107
  38. Lumachi F , Ermani M , Basso S , Zucchetta P , Borsato N , Favia G . Localization of parathyroid tumors in the minimally invasive era: which technique should be chosen? Populationbased analysis of 253 patients undergoing parathyroidectomy and factors affecting parathyroid gland detection . Endocr Relat Cancer . 2001;8:63–69
  39. Lorberboym M , Minski I , Macadziob S , Nikolor G , Schachter P . Incremental diagnostic value of preoperative 99mTc-MIBI SPECT in patients with a parathyroid adenoma . J Nucl Med . 2003;44:904–908
  40. Gayed IW , Kim EE , Broussard WF , et al.   The value of 99mTcsestamibi SPECT/CT over conventional SPECT in the evaluation of parathyroid adenomas or hyperplasia . J Nucl Med . 2005;46:248–252
  41. Krausz Y , Bettman L , Guralnik L , et al.   Technetium-99m-MIBI SPECT/CT in primary hyperparathyroidism . World J Surg . 2006;30:76–83
  42. Schillaci O , Filippi L , Danieli R , Simonetti G . Single-photon emission computed tomography/computed tomography in abdominal diseases . Semin Nucl Med . 2007;37:48–61
  43. Choi BY , Nguyen HM . The diagnosis and management of benign hepatic tumors . J Clin Gastroenterol . 2005;39:401–412
  44. Royal HD , Brown ML , Drum DE , Nagle CE , Sylvester JM , Ziessman HA . Procedure guideline for hepatic and splenic imaging. Society of Nuclear Medicine . J Nucl Med . 1998;39:1114–1116
  45. Ziessman HA , Silverman PM , Patterson J , et al.   Improved detection of small cavernous hemangiomas of the liver with high-resolution three-headed SPECT . J Nucl Med . 1991;32:2086–2091
  46. Birnbaum BA , Noz ME , Chapnick J , et al.   Hepatic hemangiomas: diagnosis with fusion of MR, CT, and Tc-99mlabeled red blood cell SPECT images . Radiology . 1991;181:469–474
  47. Schillaci O , Danieli R , Manni C , Capoccetti F , Simonetti G . Technetium-99m-labelled red blood cell imaging in the diagnosis of hepatic hemangiomas: the role of SPECT/CT with a hybrid camera . Eur J Nucl Med Mol Imaging . 2004;31:1011–1015
  48. Zheng JG , Yao ZM , Shu CY , Zhang Y , Zhang X . Role of SPECT/CT in diagnosis of hepatic hemangiomas . World J Gastroenterol . 2005;11:5336–5341
  49. Castellani M , Cappellini MD , Cappelletti M , et al.   Tc-99m sulphur colloid scintigraphy in the assessment of residual splenic tissue after splenectomy . Clin Radiol . 2001;56:596–598
  50. Gunes I , Yilmazlar T , Sarikaya I , Akbunar T , Irgil C . Scintigraphic detection of splenosis: superiority of tomographic selective spleen scintigraphy . Clin Radiol . 1994;49:115–117
  51. Horger M , Eschmann SM , Lengerke C , Claussen CD , Pfannenberg C , Bares R . Improved detection of splenosis in patients with haematological disorders: the role of combined transmission-emission tomography . Eur J Nucl Med Mol Imaging . 2003;30:316–319
  52. Valdes Olmos RA , Horenblas S , Kartachova M , Hoefnagel CA , Sivro F , Baars PC . 99mTc-labelled heat-denatured erythrocyte SPECT-CT matching to differentiate accessory spleen from tumour recurrence . Eur J Nucl Med Mol Imaging . 2004;31:150
  53. Howart DM . The role of nuclear medicine in the detection of acute gastrointestinal bleeding . Semin Nucl Med . 2006;36:133–146
  54. Yama N , Ezoe E , Kimura Y , et al.   Localization of intestinal bleeding using a fusion of Tc-99m-labeled RBC SPECT and X-ray CT . Clin Nucl Med . 2005;30:488–489
  55. Krag DN , Weaver DL , Alex JC , Fairbank JT . Surgical resection and radiolocalization of the sentinel lymph node in breast cancer using a gamma probe . Surg Oncol . 1993;2:335–340
  56. Liu SH , Chang WC , Kao PF , et al.   Lymphoscintigraphy and intraoperative gamma probe-directed sentinel lymph node mapping in patients with malignant melanoma . J Formos Med Assoc . 2004;103:41–46
  57. Chetty U , Jack W , Prescott RJ , Tyler C , Rodger A . Management of the axilla in operable breast cancer treated by breast conservation: a randomized clinical trial. Edinburgh Breast Unit . Br J Surg . 2000;87:163–169
  58. Schrenk P , Rieger R , Shamiyeh A , Wayand W . Morbidity following sentinel lymph node biopsy versus axillary lymph node dissection for patients with breast carcinoma . Cancer . 2000;88:608–614
  59. Husarik DB , Fehr M , Thuerl CM , et al.   Sentinel lymph node scintigraphy in breast cancer: incremental value of SPECT/CT imaging . J Nucl Med . 2005;46:197
  60. Husarik DB , Steinert HC . Single-photon emission computed tomography/computed tomography for sentinel node mapping in breast cancer . Semin Nucl Med . 2007;37:29–33
  61. Lerman H , Metser U , Lievshitz G , Sperber F , Shneebaum S , Even-Sapir E . Lymphoscintigraphic sentinel node identification in patients with breast cancer: the role of SPECT/CT . Eur J Nucl Med Mol Imaging . 2006;33:329–337
  62. van der Ploeg IMC , Valdes Olmos RA , Nieweg OE , Rutgers EJT , Kroon BBR , Hoefnagel CA . The additional value of SPECT/CT in lymphatic mapping in breast cancer and melanoma . J Nucl Med . 2007;48:1756–1760
  63. Huang JY, Kao PF, Chen YS. Visual Enhancement for Sentinel Lymph Node Mapping in Breast Cancer by Multiple Display Formats of SPECT/CT Images. The International Conference on Bio Medical Engineering and Informatics (BMEI2008), Hainan, China, 2008.
  64. Kao PF, Huang JY, Chen YS. SLN SPECT/CT 3D Display with Bone Co-registration. The Society of Nuclear Medicine 55th Annual Meeting, New Orleans, Louisiana, USA, 2008.
  65. Horger M , Bares R . The role of single-photon emission computed tomography/computed tomography in benign and malignant bone disease . Semin Nucl Med . 2006;36:286–294
  66. Even-Sapir E . Imaging of malignant bone involvement by morphologic, scintigraphic, and hybrid modalities . J Nucl Med . 2005;46:1356–1367
  67. Kao PF , Tzen KY , Chen JY , Lin KJ , Tsai MF , Yen TC . Rectus abdominis rhabdomyolysis after sit ups: unexpected detection by bone scan . Br J Sport Med . 1998;32:253–254
  68. Kao PF , Tzen KY , Chang LY , You DL , Yang JY . 99mTc-MDP scintigraphy in high-voltage electrical burn patients . Nucl Med Commun . 1997;18:846–852
  69. Ergun EL , Kiratli PO , Gunay EC , Erbas B . A report on the incidence of intestinal 99mTc-methylene diphosphonate uptake of bone scans and a review of the literature . Nucl Med Commun . 2006;27:877–885
  70. Loutfi I , Collier BD , Mohammed AM . Nonosseous abnormalities on bone scans . J Nucl Med Technol . 2003;31:149–153
  71. Love C , Din AS , Tomas MB , Kalapparambath TP , Palestro CJ . Radionuclide bone imaging: an illustrative review . Radiographics . 2003;23:341–358

PII: S1016-3190(08)60048-8

doi:10.1016/S1016-3190(08)60048-8

Tzu Chi Medical Journal
Volume 20, Issue 4 , Pages 253-269, December 2008