Tzu Chi Medical Journal
Volume 21, Issue 2 , Pages 110-117, June 2009

Esophageal Impedance: Role in the Evaluation of Esophageal Motility

  • Chien-Lin Chen

      Affiliations

    • Corresponding Author InformationCorresponding author. Department of Medicine, Buddhist Tzu Chi General Hospital, 707, Section 3, Chung-Yang Road, Hualien, Taiwan

Department of Medicine, Buddhist Tzu Chi General Hospital and Tzu Chi University, Hualien, Taiwan

Received 23 February 2009; received in revised form 25 February 2009; accepted 5 March 2009.

Article Outline

Abstract 

The esophagus is a hollow muscular tube with ends closed proximally and distally by muscular sphincters. The upper esophageal sphincter and proximal one third of the esophageal body are composed of striated muscle. There is then a transition zone where striated and smooth muscle mix together. The lower esophageal sphincter and the distal one half to two thirds of the esophageal body are composed of smooth muscle. Esophageal peristalsis results from sequential contraction of circular muscles, which serves to push the ingested food bolus toward the stomach with minimal stasis in the esophageal body. Therefore, esophageal motility testing aims to investigate esophageal function and to reveal any disorders to explain individual symptoms and provide a rationale for treatment. In 1991, impedance monitoring was introduced by Jiri Silny as a new technique to detect the flow of certain physical properties through hollow viscera, which later inspired numerous studies in which the possible applications of this technique were investigated. When combined with manometry, impedance provides information on esophageal bolus transit while manometry provides information on esophageal contractile activity. Subsequently, normal values for combined impedance and manometry have been reported with different methodologies worldwide, and such technique allows the acquisition of more information than manometry alone in patients with esophageal motility abnormalities. Therefore, combined impedance and manometry is emerging as an important tool for understanding and obtaining detailed information about the physiology and pathophysiology relevant to esophageal motility. Other potential clinical implications of this technique may include the functional classification of esophageal motor disturbances in patients with non-obstructive dysphagia, and the perioperative management of laparoscopic fundoplication which could impact esophageal motility. In this review, the clinical applications of this emerging new technique are summarized with regard to the technical aspects of this technology. The advantages they offer over conventional techniques for the evaluation of esophageal motor diseases are reported.

Keywords:  Esophageal motility , Esophagus , Impedance

No full text is available. To read the body of this article, please view the PDF online.

 

Back to Article Outline

References 

  1. Silny J . Intraluminal multiple electric impedance procedure for measurement of gastrointestinal motility . Neurogastroenterol Motil . 1991;3:151–162
  2. Nguyen HN , Domingues GR , Lammert F . Technological insights: combined impedance manometry for esophageal motility testing-current results and further implications . World J Gastroenterol . 2006;12:6266–6273
  3. Nguyen HN , Silny J , Albers D , et al.   Dynamics of esophageal bolus transport in healthy subjects studied using multiple intraluminal impedancometry . Am J Physiol . 1997;273:G958–G964
  4. Tutuian R , Elton JP , Castell DO , Gideon RM , Castell JA , Katz PO . Effects of position on oesophageal function: studies using combined manometry and multichannel intraluminal impedance . Neurogastroenterol Motil . 2003;15:63–67
  5. Tutuian R , Vela MF , Balaji NS , et al.   Esophageal function testing with combined multichannel intraluminal impedance and manometry: multicenter study in healthy volunteers . Clin Gastroenterol Hepatol . 2003;1:174–182
  6. Fisher MA , Hendrix TR , Hunt JN , Murrills AJ . Relation between volume swallowed and velocity of the bolus ejected from the pharynx into the esophagus . Gastroenterology . 1978;74:1238–1240
  7. Sifrim D , Blondeau K . Technology insight: the role of impedance testing for esophageal disorders . Nat Clin Pract Gastroenterol Hepatol . 2006;3:210–219
  8. Tutuian R , Castell DO . Clarification of the esophageal function defect in patients with manometric ineffective esophageal motility: studies using combined impedance-manometry . Clin Gastroenterol Hepatol . 2004;2:230–236
  9. Kahrilas PJ , Clouse RE , Hogan WJ . American Gastroenterological Association technical review on the clinical use of esophageal manometry . Gastroenterology . 1994;107:1865–1884
  10. Richter JE . Oesophageal motility disorders . Lancet . 2001;358:823–828
  11. Frieling T , Hermann S , Kuhlbusch R , et al.   Comparison between intraluminal multiple electric impedance measurement and manometry in the human oesophagus . Neurogastroenterol Motil . 1996;8:45–50
  12. Kahrilas PJ , Dodds WJ , Hogan WJ . Effect of peristaltic dysfunction on esophageal volume clearance . Gastroenterology . 1988;94:73–80
  13. Bredenoord AJ , Tutuian R , Smout AJ , Castell DO . Technology review: esophageal impedance monitoring . Am J Gastroenterol . 2007;102:187–194
  14. Fass J , Silny J , Braun J , et al.   Measuring esophageal motility with a new intraluminal impedance device. First clinical results in reflux patients . Scand J Gastroenterol . 1994;29:693–702
  15. Simren M , Silny J , Holloway R , Tack J , Janssens J , Sifrim D . Relevance of ineffective oesophageal motility during oesophageal acid clearance . Gut . 2003;52:784–790
  16. Imam H , Shay S , Ali A , Baker M . Bolus transit patterns in healthy subjects: a study using simultaneous impedance monitoring, videoesophagram, and esophageal manometry . Am J Physiol Gastrointest Liver Physiol . 2005;288:G1000–G1006
  17. Nguyen NQ , Rigda R , Tippett M , Conchillo J , Smout AJ , Holloway RH . Assessment of oesophageal motor function using combined perfusion manometry and multi-channel intra-luminal impedance measurement in normal subjects . Neurogastroenterol Motil . 2005;17:458–465
  18. Nguyen HN , Domingues GR , Winograd R , et al.   Impedance characteristics of normal oesophageal motor function . Eur J Gastroenterol Hepatol . 2003;15:773–780
  19. Tutuian R , Castell DO . Combined multichannel intraluminal impedance and manometry clarifies esophageal function abnormalities: study in 350 patients . Am J Gastroenterol . 2004;99:1011–1019
  20. Conchillo JM , Nguyen NQ , Samsom M , Holloway RH , Smout AJ . Multichannel intraluminal impedance monitoring in the evaluation of patients with non-obstructive dysphagia . Am J Gastroenterol . 2005;100:2624–2632
  21. Chen CL , Yi CH . Utility of esophageal impedance in identifying dysmotility in patients with erosive esophagitis . Dis Esophagus . 2008;21:539–543
  22. Quiroga E , Cuenca-Abente F , Flum D , Dellinger EP , Oelschlager BK . Impaired esophageal function in morbidly obese patients with gastroesophageal reflux disease: evaluation with multichannel intraluminal impedance . Surg Endosc . 2006;20:739–743
  23. Domingues GR , Winograd R , Lemme EM , et al.   Characteristics of oesophageal bolus transport in patients with mild oesophagitis . Eur J Gastroenterol Hepatol . 2005;17:323–332

PII: S1016-3190(09)60021-5

doi:10.1016/S1016-3190(09)60021-5

Tzu Chi Medical Journal
Volume 21, Issue 2 , Pages 110-117, June 2009