Esophageal Impedance: Role in the Evaluation of Esophageal Motility
Article Outline
Abstract
The esophagus is a hollow muscular tube with ends closed proximally and distally by muscular sphincters. The upper esophageal sphincter and proximal one third of the esophageal body are composed of striated muscle. There is then a transition zone where striated and smooth muscle mix together. The lower esophageal sphincter and the distal one half to two thirds of the esophageal body are composed of smooth muscle. Esophageal peristalsis results from sequential contraction of circular muscles, which serves to push the ingested food bolus toward the stomach with minimal stasis in the esophageal body. Therefore, esophageal motility testing aims to investigate esophageal function and to reveal any disorders to explain individual symptoms and provide a rationale for treatment. In 1991, impedance monitoring was introduced by Jiri Silny as a new technique to detect the flow of certain physical properties through hollow viscera, which later inspired numerous studies in which the possible applications of this technique were investigated. When combined with manometry, impedance provides information on esophageal bolus transit while manometry provides information on esophageal contractile activity. Subsequently, normal values for combined impedance and manometry have been reported with different methodologies worldwide, and such technique allows the acquisition of more information than manometry alone in patients with esophageal motility abnormalities. Therefore, combined impedance and manometry is emerging as an important tool for understanding and obtaining detailed information about the physiology and pathophysiology relevant to esophageal motility. Other potential clinical implications of this technique may include the functional classification of esophageal motor disturbances in patients with non-obstructive dysphagia, and the perioperative management of laparoscopic fundoplication which could impact esophageal motility. In this review, the clinical applications of this emerging new technique are summarized with regard to the technical aspects of this technology. The advantages they offer over conventional techniques for the evaluation of esophageal motor diseases are reported.
Keywords: Esophageal motility , Esophagus , Impedance
No full text is available. To read the body of this article, please view the PDF online.
References
- . Intraluminal multiple electric impedance procedure for measurement of gastrointestinal motility . Neurogastroenterol Motil . 1991;3:151–162
- . Technological insights: combined impedance manometry for esophageal motility testing-current results and further implications . World J Gastroenterol . 2006;12:6266–6273
- Dynamics of esophageal bolus transport in healthy subjects studied using multiple intraluminal impedancometry . Am J Physiol . 1997;273:G958–G964
- . Effects of position on oesophageal function: studies using combined manometry and multichannel intraluminal impedance . Neurogastroenterol Motil . 2003;15:63–67
- Esophageal function testing with combined multichannel intraluminal impedance and manometry: multicenter study in healthy volunteers . Clin Gastroenterol Hepatol . 2003;1:174–182
- . Relation between volume swallowed and velocity of the bolus ejected from the pharynx into the esophagus . Gastroenterology . 1978;74:1238–1240
- . Technology insight: the role of impedance testing for esophageal disorders . Nat Clin Pract Gastroenterol Hepatol . 2006;3:210–219
- . Clarification of the esophageal function defect in patients with manometric ineffective esophageal motility: studies using combined impedance-manometry . Clin Gastroenterol Hepatol . 2004;2:230–236
- . American Gastroenterological Association technical review on the clinical use of esophageal manometry . Gastroenterology . 1994;107:1865–1884
- . Oesophageal motility disorders . Lancet . 2001;358:823–828
- Comparison between intraluminal multiple electric impedance measurement and manometry in the human oesophagus . Neurogastroenterol Motil . 1996;8:45–50
- . Effect of peristaltic dysfunction on esophageal volume clearance . Gastroenterology . 1988;94:73–80
- . Technology review: esophageal impedance monitoring . Am J Gastroenterol . 2007;102:187–194
- Measuring esophageal motility with a new intraluminal impedance device. First clinical results in reflux patients . Scand J Gastroenterol . 1994;29:693–702
- . Relevance of ineffective oesophageal motility during oesophageal acid clearance . Gut . 2003;52:784–790
- . Bolus transit patterns in healthy subjects: a study using simultaneous impedance monitoring, videoesophagram, and esophageal manometry . Am J Physiol Gastrointest Liver Physiol . 2005;288:G1000–G1006
- . Assessment of oesophageal motor function using combined perfusion manometry and multi-channel intra-luminal impedance measurement in normal subjects . Neurogastroenterol Motil . 2005;17:458–465
- Impedance characteristics of normal oesophageal motor function . Eur J Gastroenterol Hepatol . 2003;15:773–780
- . Combined multichannel intraluminal impedance and manometry clarifies esophageal function abnormalities: study in 350 patients . Am J Gastroenterol . 2004;99:1011–1019
- . Multichannel intraluminal impedance monitoring in the evaluation of patients with non-obstructive dysphagia . Am J Gastroenterol . 2005;100:2624–2632
- . Utility of esophageal impedance in identifying dysmotility in patients with erosive esophagitis . Dis Esophagus . 2008;21:539–543
- . Impaired esophageal function in morbidly obese patients with gastroesophageal reflux disease: evaluation with multichannel intraluminal impedance . Surg Endosc . 2006;20:739–743
- Characteristics of oesophageal bolus transport in patients with mild oesophagitis . Eur J Gastroenterol Hepatol . 2005;17:323–332
PII: S1016-3190(09)60021-5
doi:10.1016/S1016-3190(09)60021-5
© 2009 Buddhist Compassion Relief Tzu Chi Foundation. Published by Elsevier Inc. All rights reserved.
