Tzu Chi Medical Journal
Volume 21, Issue 2 , Pages 110-117 , June 2009

Esophageal Impedance: Role in the Evaluation of Esophageal Motility

  • Chien-Lin Chen

      Affiliations

    • Corresponding Author InformationCorresponding author. Department of Medicine, Buddhist Tzu Chi General Hospital, 707, Section 3, Chung-Yang Road, Hualien, Taiwan

Received 23 February 2009 ,Revised 25 February 2009 ,Accepted 5 March 2009.

References 

  1. Silny J . Intraluminal multiple electric impedance procedure for measurement of gastrointestinal motility . Neurogastroenterol Motil . 1991;3:151–162
  2. Nguyen HN , Domingues GR , Lammert F . Technological insights: combined impedance manometry for esophageal motility testing-current results and further implications . World J Gastroenterol . 2006;12:6266–6273
  3. Nguyen HN , Silny J , Albers D , et al.   Dynamics of esophageal bolus transport in healthy subjects studied using multiple intraluminal impedancometry . Am J Physiol . 1997;273:G958–G964
  4. Tutuian R , Elton JP , Castell DO , Gideon RM , Castell JA , Katz PO . Effects of position on oesophageal function: studies using combined manometry and multichannel intraluminal impedance . Neurogastroenterol Motil . 2003;15:63–67
  5. Tutuian R , Vela MF , Balaji NS , et al.   Esophageal function testing with combined multichannel intraluminal impedance and manometry: multicenter study in healthy volunteers . Clin Gastroenterol Hepatol . 2003;1:174–182
  6. Fisher MA , Hendrix TR , Hunt JN , Murrills AJ . Relation between volume swallowed and velocity of the bolus ejected from the pharynx into the esophagus . Gastroenterology . 1978;74:1238–1240
  7. Sifrim D , Blondeau K . Technology insight: the role of impedance testing for esophageal disorders . Nat Clin Pract Gastroenterol Hepatol . 2006;3:210–219
  8. Tutuian R , Castell DO . Clarification of the esophageal function defect in patients with manometric ineffective esophageal motility: studies using combined impedance-manometry . Clin Gastroenterol Hepatol . 2004;2:230–236
  9. Kahrilas PJ , Clouse RE , Hogan WJ . American Gastroenterological Association technical review on the clinical use of esophageal manometry . Gastroenterology . 1994;107:1865–1884
  10. Richter JE . Oesophageal motility disorders . Lancet . 2001;358:823–828
  11. Frieling T , Hermann S , Kuhlbusch R , et al.   Comparison between intraluminal multiple electric impedance measurement and manometry in the human oesophagus . Neurogastroenterol Motil . 1996;8:45–50
  12. Kahrilas PJ , Dodds WJ , Hogan WJ . Effect of peristaltic dysfunction on esophageal volume clearance . Gastroenterology . 1988;94:73–80
  13. Bredenoord AJ , Tutuian R , Smout AJ , Castell DO . Technology review: esophageal impedance monitoring . Am J Gastroenterol . 2007;102:187–194
  14. Fass J , Silny J , Braun J , et al.   Measuring esophageal motility with a new intraluminal impedance device. First clinical results in reflux patients . Scand J Gastroenterol . 1994;29:693–702
  15. Simren M , Silny J , Holloway R , Tack J , Janssens J , Sifrim D . Relevance of ineffective oesophageal motility during oesophageal acid clearance . Gut . 2003;52:784–790
  16. Imam H , Shay S , Ali A , Baker M . Bolus transit patterns in healthy subjects: a study using simultaneous impedance monitoring, videoesophagram, and esophageal manometry . Am J Physiol Gastrointest Liver Physiol . 2005;288:G1000–G1006
  17. Nguyen NQ , Rigda R , Tippett M , Conchillo J , Smout AJ , Holloway RH . Assessment of oesophageal motor function using combined perfusion manometry and multi-channel intra-luminal impedance measurement in normal subjects . Neurogastroenterol Motil . 2005;17:458–465
  18. Nguyen HN , Domingues GR , Winograd R , et al.   Impedance characteristics of normal oesophageal motor function . Eur J Gastroenterol Hepatol . 2003;15:773–780
  19. Tutuian R , Castell DO . Combined multichannel intraluminal impedance and manometry clarifies esophageal function abnormalities: study in 350 patients . Am J Gastroenterol . 2004;99:1011–1019
  20. Conchillo JM , Nguyen NQ , Samsom M , Holloway RH , Smout AJ . Multichannel intraluminal impedance monitoring in the evaluation of patients with non-obstructive dysphagia . Am J Gastroenterol . 2005;100:2624–2632
  21. Chen CL , Yi CH . Utility of esophageal impedance in identifying dysmotility in patients with erosive esophagitis . Dis Esophagus . 2008;21:539–543
  22. Quiroga E , Cuenca-Abente F , Flum D , Dellinger EP , Oelschlager BK . Impaired esophageal function in morbidly obese patients with gastroesophageal reflux disease: evaluation with multichannel intraluminal impedance . Surg Endosc . 2006;20:739–743
  23. Domingues GR , Winograd R , Lemme EM , et al.   Characteristics of oesophageal bolus transport in patients with mild oesophagitis . Eur J Gastroenterol Hepatol . 2005;17:323–332

PII: S1016-3190(09)60021-5

doi: 10.1016/S1016-3190(09)60021-5

Tzu Chi Medical Journal
Volume 21, Issue 2 , Pages 110-117 , June 2009