Tzu Chi Medical Journal
Volume 19, Issue 4 , Pages 241-244 , December 2007

Measurements of Intraocular Pressure with Tono-Pen and Goldmann Applanation Tonometers in Subjects with Systemic Illness

  • Sheng-Yao Hsu

      Affiliations

    • Department of Ophthalmology, Buddhist Tzu Chi General Hospital, Hualien, Taiwan
  • ,
  • Shu-Fang Lin

      Affiliations

    • Department of Ophthalmology, Buddhist Tzu Chi General Hospital, Hualien, Taiwan
  • ,
  • Ai-Hsi Hsu

      Affiliations

    • Department of Internal Medicine, Buddhist Tzu Chi General Hospital, Hualien, Taiwan
    • Corresponding Author InformationCorresponding author. Department of Internal Medicine, Buddhist Tzu Chi General Hospital, 707, Section 3, Chung-Yang Road, Hualien, Taiwan

Received 19 April 2007 ,Revised 19 May 2007 ,Accepted 15 June 2007.

References 

  1. Bhan A , Browning AC , Shah S , Hamilton R , Dave D , Dua HS . Effect of corneal thickness on intraocular pressure measurements with the pneumotonometer, Goldmann applanation tonometer and Tono-Pen . Invest Ophthalmol Vis Sci . 2002;43:1389–1392
  2. Brandt JD , Beiser JA , Kass MA , Gordon MO . Central corneal thickness in the Ocular Hypertension Treatment Study (OHTS) . Ophthalmology . 2001;108:1779–1788
  3. Pache M , Wilmsmeyer S , Lautebach S , Funk J . Dynamic contour tonometry versus Goldmann applanation tonometry: a comparative study . Graefe's Arch Clin Exp Ophthalmol . 2005;243:763–767
  4. Sihota R , Tuli D , Dada T , Gupta V , Sachdeva MM . Distribution and determinants of intraocular pressure in a normal pediatric population . J Pediatr Ophthalmol Strabismus . 2006;43:14–18
  5. Lee AJ , Saw SM , Gazzard G , Cheng A , Tan DT . Intraocular pressure associations with refractive error and axial length in children . Br J Ophthalmol . 2004;88:5–7
  6. Morgan AJ , Harper J , Hosking SL , Gilmartin B . The effect of corneal thickness and corneal curvature on pneumatonometer measurements . Curr Eye Res . 2002;25:107–112
  7. Goldmann H , Schmidt T . Uber applanationstonometrie . Ophthalmologica . 1957;134:221–242
  8. Liu J , Roberts CJ . Influence of corneal biomechanical properties on intraocular pressure measurement: quantitative analysis . J Cataract Refract Surg . 2005;31:146–155
  9. Zadok D , Tran DB , Twa M , Carpenter M , Schanzlin DJ . Pneumotonometry versus Goldmann tonometry after laser in situ keratomileusis for myopia . J Cataract Refract Surg . 1999;25:1344–1348
  10. Hsu SY , Hsu YC , Tsai RK , Lin CP . Intraocular pressure change after laser in situ keratomileusis (LASIK) . Kaohsiung J Med Sci . 2005;21:149–152

PII: S1016-3190(10)60022-5

doi: 10.1016/S1016-3190(10)60022-5

Tzu Chi Medical Journal
Volume 19, Issue 4 , Pages 241-244 , December 2007